ГОСТ IEC 60601-1-8—2022
[25]Wiklund M. Medical Device and Equipment Design. Usability engineering and ergonomics Buffalo Grove III.:
Interpharm Press, 1995
[26]ISO 9703-2Anesthesia and respiratory care alarm signals — Part 2: Auditory alarm signals
(withdrawn)
[27]AAMI, Improving medical alarm systems, Horizons supplement, Bio Inst & Tech, 2011, spring
[28] AAMI, Clinical alarms, report from the 2011 Summit [cited 2012-07-13].
Available from Internet:
<http://www.aami.org/htsi/alarms/pdfs/2011_Alarms_Summit_publication.pdf
>
[29]AAMI TIR 66, Guidance for the creation of physiologic data and waveform databases to demonstrate reasonable
assurance of the safety and effectiveness of alarm system algorithms
[30]ISO 8201:2017
[31]
IEC TR 80001-2-5
[32]IEC 80001-1
[33]ISO 9000:2015
Alarm systems — Audible emergency evacuation signal — Requirements
Application of risk management for IT-networks incorporating medical devices —
Part 2-5: Application guidance — Guidance on distributed alarm systems
Application of risk management for IT-networks incorporating medical devices —
Part 1: Roles, responsibilities and activities
Ouality management systems — Fundamentals and vocabulary
[34] Belz S.M., Robinson G.S. and Casali J.G. (1999). A new class of auditory warning signals for complex systems:
Auditory icons. Human factors, 41(4), p. 608—618
[35] Edworthy J., Page R., Hibbard A., Kyle S., Ratnage P. and Claydon S. (2014) Learning three sets of alarms for the
same medical functions: A perspective on the difficulty of learning alarms specified in an international standard.
Applied Ergonomics 45(5) p. 1291—1296
[36] Edworthy J.R., Reid S., Mcdougall S., Edworthy J.D., Hall S., Bennett S., Khan J. and Pye E. (2017) The
recognizability and localizability of auditory alarms: setting global medical device standards. Human Factors, 59(7), p.
1108—1127
[37] Graham R. (1999). Use of auditory icons as emergency warnings: evaluation within a vehicle collision avoidance
application. Ergonomics, 42(9), p. 1233—1248
[38] Perry N.C., Stevens C.J., Wiggins M.W. and Howell C.E. (2007). Cough once for danger: Icons versus abstract
warnings as informative alerts in civil aviation. Human Factors: The Journal of the Human Factors and Ergonomics
Society, 49(6), p. 1061—1071
[39] Edworthy J., Loxley S. and Dennis I. (1991). Improving auditory warning design: Relationship between warning
sound parameters and perceived urgency. Human factors, 33(2), p. 205—231
[40] Hellier E.J., Edworthy J. and Dennis I. (1993). Improving auditory warning design: Quantifying and predicting the
effects of different warning parameters on perceived urgency. Human Factors, 35(4), p. 693—706
[41]
Haas E.C. and Casali J.G. (1995). Perceived urgency of and response time to multi-tone and frequency-modulated
warning signals in broadband noise. Ergonomics, 38(11), p. 2313—2326
[42] MondorT.A. and Finley G.A. (2003). The perceived urgencyof auditory warning alarms used inthe hospital operating
roomis in appropriate. Canadian Journal of Anesthesia, 50(3), p. 221—228
[43] Lewis B., Eisert J. and Baldwin C. (2014). Effect oft actile location, pulse duration, and interpulse interval on perceived
urgency. Transportation Research Record: Journal of the Transportation Research Board, (2423), p. 10—14
[44]Edworthy J. (2017) Ch.23 Designing Auditory Alarms. In Information Design: Research and Practice (Ed: Black A.,
Luna P., Lund O. and Walker S.). London: Routledge, p. 377—390
[45]Bolton M.L., Zheng X., Li M., Edworthy J.R. and Boyd A.D. (2019). An experimental validation of masking in IEC
60601-1-8:2006 — compliant alarm sounds. Human factors [viewed 2020-03-24]. Available at:
https://doi.
org/10.1177/0018720819862911
[46]Alali K.A. and Casali J.G. (2011). The challenge of localizing vehicle backup alarms: Effects of passive and electronic
hearing protectors, ambient noise level, and backup alarm spectral content. Noise and Health, 13(51), p. 99
99