ГОСТ Р ИСО 14708-3—2016
Библиография
[11ISO 780:1997, Packaging — Pictorial marking for handling of goods
[2] ISO 15223:2000, Medical devices — Symbols to be used with medical device labels, labelling and information to
be supplied. Amendment 1:2002. Amendment 2:2004
[3]European Pharmacopoeia. 3rd edition. 1977 (Council of Europe)
[4]ISO 10993-1:2003. Biological evaluation of medical devices — Part 1: Evaluation and testing
[5]ISO 14971:2007. Medical devices — Application of risk management to medical devices
[6]ISO 14155-1:2003. Clinical investigation of medical devices for human subjects — Part 1: General requirements
[7] ISO 14155-2:2003. Clinical investigation of medical devices for human subjects — Part 2: Clinical investigation
plans
(8J1ЭОЯР 14283:2004, Implants for surgery — Fundamental principles
[9]WUST et al 1995, Int. J. Hyperthermia. 11. pp. 151— 167
[10]Electric and magnetic fields associated with the use of electric power. NIEHS. June 2002
[11]World Health Organization (WHO) web site
(http://wwiv.who.int/peh-emf/en/
)
[12]National Grid Company (Warwick. UK) EMF web site
(http://www.emfs.info/default.asp
)
[13] Children’s exposure to magnetic fields produced by U.S. television sets used for viewing programs and playing
video games. Bioelectromagnetics. 21. pp. 214—227. 2000. Tables 3 and 4 combined
[14] IEC/TR 61000-2-7:1998. Electromagnetic compatibility (EMC) — Part 2: Environment — Section 7: Low frequency
magnetic fields in various environments
[15] IEC.TR 61000-2-3:1992. Electromagnetic compatibility (EMC) — Part 2: Environment — Section 3: Description of
the environment — Radiated and non-network-frequency-related conducted phenomena
[16] RICKLI H. et al.. Induction ovens and electromagnetic interference: What is the risk for patients with implanted
pacemakers? PACE. 26. pp. 1494— 1497. 2002
[17] BINGGELI. et al.. Induction ovens and electromagnetic interference: What is the risk for patients with implanted
cardioverter defibrillators? J. Cardio Electrophysiol..16. pp. 399—401, 2005
[18] HIROSE. et al.. Electromagnetic interference of implantable unipolar cardiac pacemakers by an induction oven.
PACE. 28. pp. 540—548. 2005
[19] ICNIRP Guidelines:1998. Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic
fields (up to 300 GHz). Health Physics Society
[20] IEEE C95.1:1999. StandardforSafetyLevelswith Respectto Human Exposure to RadioFrequencyElectromagnetic
Fields. 3 kHz to 300 GHz
[21] IEEE C95.6:2002. Standard for Safety Levels with Respect to Human Exposure to Electromagnetic Fields.
0—3 kHz
[22] MIL-STD-461E:1999. Test Specifications — Requirements for the Control of Electromagnetic Interference
Characteristics of Subsystems and Equipment
[23] IEC/TS 61000-2-5:1995. Electromagnetic compatibility (EMC) — Part2-5: Environment — Sect»on5: Classification
of electromagnetic environments
[24] IEC62226-2-1:2004. Exposure toelectricor magnetic fields in the lowand intermediate frequency range— Methods
for calculating the current density and internal electric field induced in the human body — Part 2-1: Exposure to
magnetic fields — 2D models
[25]TILLEY. A. R.. Henry Dreyfuss Associates. The measure of man and woman, human factors in design. John Wiley
& Sons. 2002
[26]Additional anthropometric data: <http?Avww.roymech.co.uk/lJseful_Tables/Human.lHuman_sizes.html>
[27] SCHOLTEN.A. and SILNYJ., The interference threshold ofunipolarcardiac pacemakers in extremely low frequency
magnetic fields. J. Medical Engineering and Technology. 5. pp. 185— 194, 2001
[28] CISPR 11:2004. Industrial, scientific and medical (ISM) radio-frequencyequipment— Electromagnetic disturbance
characteristics — Limits and methods of measurement
[29]CISPR 14-1:2005. Electromagnetic compatibility — Requirements for household appliances, electric tools and
similar apparatus — Part 1: Emission
[30] CISPR 22:2006, Information technology equipment — Radio disturbance characteristics — Limits and methods
of measurement
[31]FCC 47 CFR. Part 15. Telecommunication — Radio frequency devices
[32]ISO 31 (all parts). Quantities and units
40