ГОСТ Р ИСО 16017-2—2007
Библиография
[21 ISO 6141:2000
[31 ISO 6145-1:2003
[11 prEN 13528-3:2001Ambient air quality — Diffusive samplers for the determination of gases and vapours —
Part 3: Guide to selection, use and maintenance
И1
ISO 6145-3:1986
[51
ISO 6145-4:2004
[6J
ISO 6145-5:2001
[71
ISO 6145-6:2003
Gas analysis — Requirements for certificates for calibration gases and gas mixtures
Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods
— Part 1: Methods of calibration
Gas analysis — Preparation of calibration gas mixtures — Dynamic volumetric methods —
Part 3: Periodic injections into a flowing gas stream
Gas analysis — Preparation of calibration gas mixtures — Dynamic volumetric methods —
Part 4: Continuous syringe injection method
Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods
— Part 5: Capillary calibration devices
Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods
— Part 6: Critical orifices
[81
Wright. M. D. (1993). Diffusive uptake rates for the Perkin Elmer tube — BCR air sampling intercomparison at Vito.
Mol. Belgiu Feb 1991 — April 1992. HSE internal report. IR/L/IA/93/3, Health and Safety Laboratory. Broad Lane.
Sheffield S3 7HQ. UK
[91Sternberg, J. C. et al. The mechanism of response of flame ionization detectors. 3r<1Intern. Symp. Gas Chromat.,
(1960), pp. 231 — 267
[10] EN 838
[11] EN 13528-2
Workplace atmospheres — Diffusive samplers for the determination of gases and vapours
— Requirements and test methods
Ambient air quality — Diffusive samplers for the determination of concentrations of gases
and vapours — Requirements and test methods — Part 2:Specific requirements and test
methods
[12]Knoeppel. H.. Versino. B.. Schlitt. H.. Peil. A.. Schauenburg, H.. Vissers. H. Organicsinair. Sampling and identification.
Proceedings of the first European Symposium on physico-chemical behaviour of atmospheric pollutants. ISPRA.
16— 18 October 1979. pp. 25 — 40. Commission of the European Communities. Brussels-Luxembourg 1980
[13]Dulson. W. Organisch-chemische Fremdstoffe in atmospharischer Luft. Schriftenreihe des Vereins fur Wasser-.
Boden- und Lufthygiene Nr. 47. Stuttgart: Gustav-Fischer-Vertag (1978)
[14] Bertoni. G.. Bruner. F.. Liberti. A.. Perrino. C. Some critical parameters in collection, recovery and chromatographic
analysis of organic pollutants in ambient air using light adsorbents. J. Chromat.. 203 (1981), pp. 263 — 270
[15] Vidal-madjar. C.. Gonnord. M.-F.. Benchah. F.. Guiochon. G.: Performances of various adsorbents for the trapping
and analysis of organohalogenated air pollutants by gas chromatography. J. Chromat. Sci.. 16 (1978). pp. 190 — 196
[16] Health and Safety Executive (1995). Methods for the Determination of Hazardous Substances. Volatile organic
compounds in air — Laboratory method using diffusive solid sorbent tubes, thermal desorption and gas chroma
tography. MDHS 80. HSE: London
[17]Health and Safety Executive (1991). Methods for the Determination of Hazardous Substances. Analytical quality in
workplace air monitoring. MDHS 71. HSE: Health and Safety Laboratory, Broad Lane. Sheffield. S3 7HQ, UK
[18] EN 482Workplace atmospheres — General requirements for performance of procedures for the
measurement of chemical agents
[19]Peters. R.. Hafkenscheid. T. Testing of tube-type diffusive samplers for monitoring VOC m ambient air. The
Diffusive Monitor. 7 (1995). pp. 8 — 9
[20]Erlap data in reference [11]
[21] Brown. V. M.. Crump. D. R.. Gardiner. D.. YU. C. W. F. Long-term diffusive sampling of volatile organic compounds
in indoor air. Environ. Technol., 14 (1993). pp. 771 — 777
[22] Rant. N. T.. Wright M. D. European Diffusive Sampling Initiative: Project report with status at March 1998. IACS
98/01. Health and Safety Laboratory. Sheffield S3 7HQ, UK
[23]NMI field data in reference [11]
[24] BP data in Downing. С. E. H.. Campbell. G. W., Bailey, J. C. A survey of sulphur dioxide, ammonia and hydrocarbon
concentrations in the United Kingdom, using diffusion tubes: July to December 1992. UK Environmental Technology
Executive Agency. Report LR 964 Contract no PECQf7/12/76 (1994)
[25]Reffer H.-U., Breuer L.. Ellermann. K. Materialien No. 46. Validation of Passive Samplers for Measurements of
Hydrocarbons In Ambient Air. Editor: Landesumweltamt Nordrhein-Westfalen (North-Rhine-Westphalia State
Environment Agency). Wallneyer Str. 6, Essen. Germany, p. 92 (1998) (ISSN 0947-5206)
[26]NMI field data in reference [11]
[27]Study of sorbing agents for the sampling of volatile compounds from air. EC Contract MAT1CT92-0038. Final
Report (1995)
34