ГОСТ Р ИСО 14242-3—2013
Библиография
[1]ИСО 7206-1 Имплантаты для хирургии. Частичные и тотальные протезы бедренного
сустава. Часть 1. Классификация и обозначение размеров
[2]Calonius, О. and Saikko. V., Analysis of relative motion between femoral head and
acetabular cup and advances in computation of the wear factor for the prosthetic hip joint. 3rd International
Conference on Advanced Engineering Design (AED 2003). Prague. June 2003
[3]Calonius. O. and Saikko, V., Force track analysis of contemporary hip simulators. Journal of
Biomechanics. 36. pp. 1719 - 1726. 2003
[4]Essner, A.. Schmidig, G. and Wang. A.. The clinical relevance of hip joint simulator testing: In
vitro and in vivo comparisons. Wear 259. pp. 882 - 886, 2005
[5]Saikko. V. and Calonius, 0., Slide track analysis of the relative motion between femoral head
and acetabular cup in walking and in hip simulators. Journal of Biomechanics. 35. pp. 455 - 464. 2002
[6]Saikko. V. and Calonius. O.. Slide track analysis of eight contemporary hip simulator designs.
Journal of Biomechanics, 35.1439 to 1450. 2002
[7]Saikko, V. and Calonius, O., An improved method of computing the wear factor for total hip
prostheses involving the variation of relative motion and contact pressure with location on the bearing
surface. Journal of Biomechanics. 36. 2003
[8]Saikko. V.. Calonius. O. and Keranen, J., Effect of extent of motion and type of load on the
wear of polyethylene in a biaxial hip simulator. J. Biomed. Mater. Res. Part B: Appl. Biomater., 65B. pp. 185 -
192. 2003
[9JWang. A.. Sun. D.C., Yau, S.-S., Edwards. B.. Sokol, M., Essner, A.. Polineni, V.K.. Stark. C.
and Dumbleton, J.H., Orientation softening in the deformation and wear of ultra-high molecular weight
polyethylene. Wear 234, pp. 230 - 241.1997
[10]Wang. A.. Polineni. V.K.. Essner. A.. Sokol. M.. Sun. D.C.. Stark. C. and Dumbleton. J.H.,
The significance of non-linear motion in the wear screening of orthopaedic implant materials. Journal of
testing and evaluation. 25. No 2. pp. 239 - 245.1997
[11]Wang. A.. A unified theory of wear for ultra-high molecular weight polyethylene in multi
directional sliding. Wear. 248. pp. 38 - 47. 2001
[12]Wang. A.. Essner. A.. Polineni, V.K.. Stark. C. and Dumbleton. J.H.. Lubrication and wear of
ultra-high molecular weight polyethylene in total joint replacements. Tribology International, 31. Nos 1 - 3,
pp. 17-38,1993
[13]Wang. A.. Essner. A. and Cooper. J.. The clinical relevance of hip simulator testing of high
performance implants. Seminars in Athroplasty, 17, pp. 49 - 55. 2006
10