ГОСТ Р 70168—2022
[
]
Библиография
Ш
ISO 898-7
[
2
]
ISO/TS 13498
[3]
ASTM F543-07
Mechanical properties of fasteners — Part 7: Torsional test and minimum torques for bolts and
screws with nominal diameters 1 mm to 10 mm (Механические свойства крепежных изделий.
Часть 7. Испытание на кручение и минимальные крутящие моменты для болтов и винтов
номинальных диаметров от 1до 10 мм)
Dentistry — Torsion test of implant body/connecting part joints of endosseous dental implant
systems (Стоматология. Испытание на крутящий момент сочленений имплантата с соедини
тельной деталью системы зубного импланта)
Standard specification and test methods for metallic medical bone screws
[4]
Andersson B., Odman P., Carlsson L., Branemark P.l. A new Branemark single tooth abutment: handling and early
clinical experiences. Int. J. Oral Maxillofac. Implants. 1992, 7 (1) pp. 105—111
[5]
BalfourA., & O’Brien G.R. Comparative study of antirotational single tooth abutment. J. Prosthet. Dent. 1995, 73 (1)
pp. 36—43
[
6
]
Cardoso M., Torres M.F., Lourengo E.J., De Moraes Telles D., Rodrigues R.C., Ribeiro R.F. Torque removal
evaluation of prosthetic screws after tightening and loosening cycles: an
in vitro
study. Clin. Oral Implants Res. 2012, 23
pp. 475—480
[7]
Guzaitis K.L., Knoernschild K.L., Viana M.A. Effect of repeated screw joint closing and opening cycles on implant
prosthetic screw reverse torque and implant and screw thread morphology. J. Prosthet. Dent. 2011, 106 (3) pp.
159—169
8
]
Khraisat A., Hashimoto A., Nomura S., Miyakawa O. Effect of lateral cyclic loading on abutment screw loosening of
an external hexagon implant system. J. Prosthet. Dent. 2004, 91 (4) pp. 326—334
[9]
Kim S.K., Koak J.Y., Heo S.J., Taylor T.D., Ryoo S., Lee S.Y. Screw loosening with interchangeable abutments in
internally connected implants after cyclic loading. Int. J. Oral Maxillofac. Implants. 2012, 27 (1) pp. 42—47
[
10
]
Yao K.T., Kao H.C., Cheng C.K., Fang H .W., Yip S.W., Hsu M.L. The effect of clockwise and counterclockwise
twisting moments on abutment screw loosening. Clin. Oral Implants Res. 2012, 23 (10) pp. 1181—1186
[
11
Piermatti J., Yousef H., LukeA., Mahevich R., Weiner S.An
in vitro
analysis of implant screw torque loss with external
hex and internal connection implant systems. Implant Dent. 2006, 15 (4) pp. 427—435
[
12
]
Watanabe F. Torsion test at the interface between implant and abutment. Conference Program of 13th Biennial
Meeting of International College of Prosthodontists. Cape Town, South Africa. 10—13 Sep. 2009, pp. 172—173
[13] Jorge J .R., Barao V.A., Delben J.A.,Assuncao W.G. The role of implant/abutment on torque maintenance of retention
screws and vertical misfit of implant-supported crowns before and after cycling. Int. J. Oral Maxillofac. Implants.
2013,28 (2) pp. 415-422
[14] Rangert B., JemtT., Jorneus L. Forces and moments on Branemark implants. Int. J. Oral Maxillofac. Implants. 1989,
4 (3) pp. 241—247
[15] Yokoyama D., ShinyaA., Lassila L.V., Gomi H., Nakasone Y., Vallittu P.K., ShinyaA. Framework design of an anterior
fiber-reinforced hybrid composite fixed partial denture: a 3D. Int. J. Prosthodont. 2009, 22 (4) pp. 405—412
[16] Jemt T, & Pettersson finite element study P. A 3-year follow-up study on single implant treatment. J. Dent. 1993,
21 (4) pp. 203—208
[17] Goodacre C.J., Kan J.Y., Rungcharassaeng K. Clinical complications of osseointegrated implants. J. Prosthet. Dent.
1999, 81 (5) pp. 537—552
[18] Theoharidou A., Petridis H.P, Tzannas K., Garefis P. Abutment screw loosening in singleimplant restoration: a
systematic review. Int. J. Oral Maxillofac. Implants. 2008, 23 (4) pp. 681—690
[19] Katsuta Y., & Watanabe F. Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic
loading test at the initial stage. Dent. Mater. J. 2015, 34 (6) pp. 896—902
7