ГОСТ Р ИСО 16000-10—2009
Библиография
(1)ISO 12460-1
(2]ISO 16000-3:2001
Wood-based panels — Determination of formaldehyde release — Part 1: Formaldehyde
emission by the 1-cubic metre chamber method. (ИСО 12460-1 Плиты древесные. Опре
деление выделения формальдегида. Часть 1. Метод определения выделения фор
мальдегида с применением камеры вместимостью 1 кубический метр)
Indoor air — Part 3: Determination of formaldehyde and other bonylcompounds — Active
sampling method. (ИСО 16000-3:2001 Воздух замкнутых помещений. Часть 3. Опре
деление содержания формальдегида и других карбонильных соединений. Активный
отбор проб)11
13)ЕСА (European Collaborative Action «Indoor Air Quality and its Impact on Man»). Total Volatile Organic Compounds
(TVOC) In Indoor Air Quality Investigations. Report No 19, EUR 176/5 EN. Luxembourg: Official Publications of the
European Communities. 1997
(4) ECA (European Collaborative Action «Indoor Air Quality and its Impact on Man»). Evaluation of VOC Emissions from
Building Products — Solid Flooring Materials. Report No. 18. EUR 17334 EN Luxembourg: Official Publications of the
European Communities. 1997
(5) Danish Standard/INF 90 «Directions for the determination and evaluation of the emission from building products»
(Anvlsnlng for bestemmelse og vurdenng af afgasnmg fra byggevarer). Dansk Standard.
Kebenhavn. 1994
(6JECA. Guideline for the Characterization of Volatile Organic Compounds Emitted from Indoor Materials and Products
Using Small Test Chambers, 1991, Joint Research Centre
(7JNielsen. P.A., Jensen. L.K.. Eng. K.. Bastholm. P.. Hugod. C.. Husemoen. T.. Meihave. L.. Wolkoff. P. (1994)
Health-Related Evaluation of Building Products Based on Climate Chamber Tests. IndoorAir 1994.4. pp. 146 — 153
(8) Tlchenor. B.A. Indoor air sources: using small environmental test chambers to characterize organic emissions from
indoor materials and products. EPA-600 8-89-074. Air and Energy Engineering Research Laboratory. U.S.
Environmental Protection Agency. 1989. Section 6C
(9) ECA. European Collaborative Action — Indoor Air Quality and its Impact on Man. COST Project 613. Formaldehyde
Emissions from Wood Based Panels: Guideline for the establishment of Steady state Concentrations in Test
Chambers. Report No. 2. EUR 12196 EN
(10) Tlchenor. B.A. Indoor air sources: using small environmental test chambers to characterize organic emissions from
indoor materials and products. EPA-600 8-89-074. Air and Energy Engineering Research Laboratory. U.S.
Environmental Protection Agency. 1989. Section 7
(11) Gustafsson. H. and Jonsson. B. «Review of small devices for measuring chemical emission from materials».
Report 1991:25. Swedish National Testing and Research Institute. BorAs. 1991
(12) Roache. N.. Guo. Z.. Fortmann. R. and Tlchenor. B.A. Comparing the Field and Laboratory Emission Cell (FLEC) with
Traditional Emissions Testlng Chambers. Ttchenor. B. (ed) Characterizing Sources of Indoor Air Pollution and Related
Sink Effects Sinks. Philadelphia. ASTM STP 1287. 1996. pp. 98 — 111
(13) Wolkoff. P. An emission cellfor measurement of volatile organic compounds emitted from building materials for indoor
use — the field and laboratory emission cell FLEC3*.Gefahrstoffe — RemhaltungderLuft. 56.1996. pp.151 — 157
(14) Wolkoff. P., Clausen. P.A. and Nielsen. P.A. Application of Field and Laboratory Emission Cell «FLEC»
— Performance Study. Intercomparison Study, and Case Study of Damaged Linoleum. Indoor Air, 5.1995. pp. 196 —
203
(15) Wolkoff. P., Clausen. P.A.. Nielsen. P.A. and Gunnarsen. L. «Documentation of Field and Laboratory Emission Cell
«FLEC» — Identification of Emission Processes from Carpet. Linoleum, Paint,and Sealant by Modelling». IndoorAir.
3.1993, pp. 291 — 297
(16) Wolkoff. P.. Clausen. P.A.. Nielsen. P.A.. Gustafsson. H.. Jonsson. B. and Rasmusen. E. Field and Laboratory
Emission Cell: FLEC. Healthy Buildings ’91. American Society of Heating. Refrigerating, and Air-Conditioning
Engineers. Atlanta. 1991. pp. 160 — 165
(17) Wolkoff. P. Impact of air velocity, temperature, humidity, and air on long-term VOC emissions from building products.
Atmospheric Environment. 32, 1998. pp. 1 — 11
(18) Additional Information about FLEC*2* applications can be found on the Internet address: http./i’
www.flec.com
(19) ISO 1302:2002Geometrical Product Specifications (GPS)— Indication of surface texture In technical
product documentation. (ISO 1302:2002 Геометрические характеристики изделий
(GPS). Обозначение текстуры поверхности в технической документации на продук
цию)3*
’* ISO 16000-3:2001 соответствует ГОСТ Р ИСО 16000-3—2007 «Воздух замкнутых помещений. Часть 3.
Определение содержания формальдегида и других карбонильных соединений. Активный отбор проб».
2| FLEC® (Field and Laboratory Emission Cell) — торговое наименование эмиссионной ячейки фирмы
СНЕМАТЕС. Данная информация приведена для удобства пользователей стандарта и не служит рекламой данной
продукции. Допускается использовать другую продукцию, если с ее помощью можно получить аналогичные резуль
таты.
31 Официальный перевод этого стандарта находится а Федеральном информационном фонде.
15