ГОСТ Р ИСО 15745-3-2010
,
,
[Раrams]
Paraml -О,,,0x0010,2,2,* Target Error Codes’,
"","",0,OxFFFP,О,0,0,0,0,0,0,0,0,0;
ProxyParaml - О,,,0x0000,2,2,"input size”,
Module,Module, Module
,
0 0 0
,0.
,
,
,,0 ;
ProxyParamSizeAdderl - 4, 4,4;
[Assembly]
Asseml - "connection input format",,,,,,
32,Paraml,
,ProxyAsseml,
,ProxyAssem2;
ProxyAsseml - "real time input format","20 7D 24 SLOT 30 0A",,.,,
ModuleMemberList ;
ProxyAssem2 - "real time status format","20 7D 24 SLOT 30 0B",,,,,
ModuleMemberList;
[Connection Manager]
ProxyConnectl - 0x010100002, 0x44244401,
2, 0, , 2, ProxyParaml, Asseml, , , , , "Listen Only",
"01 SLOT_MINUS_ONE 20 04 24 03 2C 04 2C 02";
РисунокA.15—Примервходов ProxyParam и ProxyAsscm
[Params]
ProxiedParaml - ,,,,,,"input size"0,2,2,
[Assembly]
ProxiedAsseml - "real time input format",,,,,;
ProxiedAssem2 - "real time status format",,,,,,16,;
[Connection Manager]
ProxiedConnectl - ,,,0,
РисунокA.16—Примерсоответствующихвходов ProxicdPlirani иProxicdAsscm
A.4.2 Специальные iреновацияк EDS вControlNet
A.4.2.1 Содержание EDS иContralNet
Данный подразделустанавливаеттребования к кодировке в EDS всетях ControlNet.
Втаблице А.29 в обобщенном виде приводится структура секций, которые м о т бып» представлены
в ControlNet EDS, соответствующие принятые ралраничители секции и порядок этих секций в EDS.
Некоторые изэтих секций являются общими для ряда основанных на CIPсетей, и ихспециальное приме
нение вControlNet указано далее в А.4.2.2. Друте секции, специфические для ControlNet, рассмотрены
вА.4.2.4.
ТаблицаА.29 —Структурафайла EDS вControlNet
Имясекции
Принятый ранриничкгель
Размещение
Требуемая/опциона.
1
ьная
1
(F.lel
(Device|
|DeviceClassification]
2
4)
File Description
Device Descnption
Device Classification
ParameterClass
(ParamClass]
4)
Требуемая
Требуемая
Требуемая
Опциональная
117