Хорошие продукты и сервисы
Наш Поиск (введите запрос без опечаток)
Наш Поиск по гостам (введите запрос без опечаток)
Поиск
Поиск
Бизнес гороскоп на текущую неделю c 29.12.2025 по 04.01.2026
Открыть шифр замка из трёх цифр с ограничениями

ГОСТ Р ИСО 7168-1-2005; Страница 46

или поделиться

Страница 46
Страница 1 Untitled document
site
_
zone
_
type
_
code =; 3
site
_
zone
_
characterization =;" natural*: "lakeside*
site
_
zone
_
characterization
_
code =; 1040
sitejnhabitans =; 5000*
site
_
emission
_
sources =; ’agriculture* ; "nature*
site
_
emission
_
sources
_
code =; 1536
site
_
traffic
_
volume =: "low*
site
_
lorry
_
percentage =; 10
site
_
street
_
type =; "wide"
site
_
traffic
_
situation =;open area"
[site
_
record]
site
_
net\vork
_
country
_
code =; "24005.24.FR"
site
_
name =;Brancolar"
site
_
address =; “Address of the site"
site
_
responsible =;Responsible Person"
site
_
start
_
time =; "1992-06-01.00-00-00"
site
_
end
_
time =; "9999-99-99.99-99-99*
site
_
type =; "background"
site
_
scale"regional";national"
site
_
scale
_
code =; 6
site
_
time
_
minus
_
UT =; *0000-00-00.02-00-00
sitejatitude =; "+434332.00*
sitejongitude =; "+0071623.00*
site
_
altitude =; "+162"
site
_
geodesic
_
system =; "WGS84"
site
_
zone
_
type =; "rural"
site
_
zone
_
tуpe
_
code =; 3
site
_
zone
_
characterization =; "natural"; "lakeside"
site
_
zone
_
characterization
_
code =; 1040
sitejnhabitans =; 5000*
site
_
emission
_
sources =; ’agriculture";nature"
site
_
emission
_
sources
_
code =; 1536
site
_
traffic
_
volume =; "low*
site
_
lory
_
percentage =; 10
site
_
street
_
type =; "wide"
site
_
traffic
_
situation =;open area”
[measurand
_
group]
[measurand
_
record]
measurand
_
code =; "08"
measurand
_
name =; "ozone"
measurand
_
unit =; "microgram per cubic meter”
measurement
_
method =;ultraviolet method*
measurement
_
method
_
standard =; "ISO 13964*
measurement
_
type =; ’automatic"
measurement
_
device =; "Manufacturer - XY 67"
mearurement
_
start
_
time =; *1993-01-01.00-00-00"
mearurement
_
end
_
time =; *99-99-99.99-99-99"
calibration
_
method =; "UV lamp"
calibration
_
method
_
standard =; "not applicable"
calibration
_
type =; ’automatic*
calibration
_
period =; 0000-00-01.00-00-00
reference
_
temperature =; 20,0
reference
_
temperature
_
unit =; degree Celsius"
reference
_
pressure =; 101,3
reference
_
pressure
_
unit =; "kilopascal"
length
_
unit =; "meter"
samplingjocation =; "free air flov/*
sampling
_
height =; 3
sampling line length =; 4.5
kwerjim it =; 0
upperjimit =; 200